Keyword: rfq
Paper Title Other Keywords Page
MOPGF137 Interlock of Beam Loss at Low Energy Part of J-PARC Linac DTL, operation, linac, detector 1
 
  • A. Miura, Y. Kawane, N. Kikuzawa, T. Maruta
    JAEA/J-PARC, Tokai-mura, Japan
  • T. Miyao
    KEK, Ibaraki, Japan
 
  J-Parc linac has developed the output beam power by increasing of acceleration energy and the peak beam current. The beam loss is getting serious along with increasing the output beam power, however, the beam loss caused at the low energy part is difficult to detect due to the low energy radioactive emission. An interlock system has been developed to prevent from the sufficient material activation using the beam current monitors. In the system, an electrical circuit to take the beam transmission between two beam current monitors is newly designed and fabricated. This paper describes the performance of the electrical circuit and the system configuration will be introduced.  
 
MOPGF146 Safety Interlock System for a Proton Linac Accelerator controls, ion, ion-source, power-supply 1
 
  • Y. Zhao, Y.Y. Du, J. He, F. Liu, Q. Ye
    IHEP, Beijing, People's Republic of China
 
  The C-ADS Injector-I is an experimental proton machine in IHEP. An interlock system based on redundancy PLC was developed for machine protection and personnel safety. Device status, radiation dose, temperature of cavities and chambers are collected for machine state judge and interlock. A MPS (Machine Protection System) work together with the interlock system in the control loop, and protect the machine in four levels for different situation.